Error 9703 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Temperature has exceeded that permitted in the motor.
Detection
On startup or normal operation of the system.
Cause
The engine exceeds the maximum permissible temperature. The possible causes are:
- The motor temperature measuring cables (position sensor cable) or the temperature sensor are in poor condition.
- The application demands high current peaks.
Solution
The possible solutions are:
- Stop the system for several minutes and decrease the effort demanded from the drive.
- Cool the motor.