Error 9523 · CNCelite 8058 / 8060 / 8065 / 8070
Message: ABSIND: Synchronism error.
Detection
On startup or normal operation of the system.
Cause
The drive has lost synchronization with the ABSIND module, which may have caused a wrong position reading. The error is likely due to a malfunction of the ABSIND module or a connection problem between the ABSIND module and the drive.
Solution
Check the connection of the encoder and the level of the signals provided by the feedback device. If "Current value = 1", feedback selected in SPEEDFBID; if "Current value = 2", feedback selected in POSITIONFBID.