Error 9340 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Sercos counter: sets with same COUNTERID must have the same parameter(s):

Detection

On CNC power-up or when validating the machine parameters.

Cause

Several sets that having the same feedback input of an RCS-S module (parameter COUNTERID) do not have the same value in one of the following parameters:

FEEDBACKTYPE, SSITYPE, SSI, I0TYPE, ABSOFF, EXTMULT, REFPULSE, I0CODDI1, I0CODDI2, NPULSES and FBACKAL'

Solution

On sets with the same COUNTERID, define the indicated parameters with the same value.

·