Error 9336 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Incompatible machine parameters
Detection
On CNC power-up or when validating the machine parameters.
Cause
There are two features incompatible with each other. The related machine parameters appear in the error message (for example, parameters HBLS and MODBUSSVRRS are incompatible because they both use the serial line).
Solution
Cancel one of the two parameters mentioned in the error message.