Error 9313 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Wrong DRIVEID of the axis of the MULTIAXIS group in the system
Detection
On CNC power-up or when validating the machine parameters.
Cause
There is no axis in the system having the same DRIVEID as the one indicated when defining a MULTIAXIS group.
Solution
Assign a DRIVEID insde the MULTIAXIS groups that is associated with the axes of the system.