Error 8223 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: The M functions are mutually exclusive or identical

Detection

During editing and execution in MDI.

Cause

An M function has been programmed more than once in the same block or there are two incompatible M functions in the same block.

Solution

An M function can only be programmed once in a block. Refer to the programming manual to check the incompatibility of the M functions.

·