Error 6062 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Emergency relay open due to a bus reinitialization error.
Detection
Following a CNC reset or during machine parameter validation.
Cause
During machine parameter reset or validation, it was not possible to successfully complete the execution of the process due to an error arising after the reassembly of the CAN bus or the Sercos ring. As a result, the emergency relay has been left open.
VALUE 1 Sercos error during a CNC reset process.
VALUE 2 CAN error during a CNC reset process.VALUE 3 Sercos and CAN error during a CNC reset process.
VALUE 4 Sercos error during a CNC validation process for the machine parameters.
VALUE 8 CAN error during a CNC validation process for the machine parameters.
VALUE 12 Sercos and CAN error during a CNC validation process for the machine parameters.
Solution
Correct the CAN or Sercos issue preventing the emergency relay from closing.