Error 5061 · CNCelite 8058 / 8060 / 8065 / 8070
Message: PLC not compatible with HMIelite.
Detection
During CNC startup.
Cause
The PLC mark PLCELITECOMP is deactivated.
Solution
Start CNC with standard HMI (parameter HMIELITE) or adapt the PLC to HMIelite and activate the PLCELITECOMP mark. The operation of the CNC working modes (manual, automatic, etc.) is different in HMIelite, so the PLC program must be adapted. Fagor provides a PLC subroutine that allows the same PLC program to run on both HMIs. An example of this subroutine can be found in ..\Mtb\Plc\Project. It is the OEM's responsibility to adapt the subroutine to the machine ensuring that the PLC complies with all safety aspects. Once the subroutine has been adapted, the PLCELITECOMP flag must be activated.
8058 80608065 8070 ꞏ191ꞏ 6000-6999