Message: Error in bus operation phase.
Detection
During CNC startup.
Cause
An internal error occurred during the configuration phase of slaves connected to the bus. In the case of EtherCAT (additional ID error code 330-xxx), it is possible that a node is in error or that the ENI configuration file is incorrect.
Solution
The possible solutions are:
- One of the slaves connected to the bus may be in an error state. Review additional errors that the CNC may be reporting to diagnose what may be causing the error.
- Regenerate the ENI configuration file using the KPA tool, following the appropriate steps to generate the file. Perform a "Detach Master" in the KPA configurator before exporting the ENI file.
- If the error repeats, please contact Fagor Automation.