Error 3077 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Single-block mode not allowed in this RETRACE process, cancel Single-block mode

Detection

During execution.

Cause

An attempt was made to activate the block-by-block mode during the retrace with a program with many blocks with very short movements.

Solution

To avoid saturating system resources, the CNC does not allow the block-by-block function for these types of programs.

·