Error 2559 · CNCelite 8058 / 8060 / 8065 / 8070
Message: #G81: R >= Z + L.
Detection
During block preparation.
Cause
Does not meet the condition:
- R (higher level) >= Z (drilling depth) + L (distance from the bottom of the drill hole where only Z moves).
Solution
Program the R Z L coordinates so that R >= Z + L is satisfied.