Error 24501 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Defective UM supply voltage.

Detection

On the diagnostic screen, during execution.

Cause

An EtherCAT node has sent an emergency indicating this error condition.

Solution

It is recommended to consult the specific manual of the node, the diagnostic information or the additional value accompanying the error (hexadecimal code of the emergency).

ID. Meaning.

0x0000 No error.0x2310 Digital output overcurrent error.

0x2311 Over-current error in group 1 digital outputs.

Outputs 1 (bit 0) to 16 (bit 15). Bit at 1 in the outputs with error.

0x2312 Over-current error in group 2 digital outputs.

Outputs 17 (bit 0) to 32 (bit 32). Bit at 1 in the outputs with error.

0x3200 Analogue I/O board internal voltage error (+15 V/-15 V).

0x3300 Analogue output overcurrent error.0x5000 RAM error.

Analogue I/O offset recording error.

PT100 calibration error.

0x5030 PT100 broken or not connected.

0x5112 Error or warning. There is no +24 V supply to the digital I/O board.

0x6010 The module has been restarted after a Watchdog.

0x6100 Internal software emergency.

Error: Assert.

Warning: CRC does not match.

0x6200 User software emergency.

A HardFault has occurred.

0x7000 Warning. The analogue board identifier reading does not match the initial reading.

0x8100 Synchronization error.0x8130 Synchronism error.

0x8210 Error in process data length (data ignored).

0x8220 Error in process data length (data used).

8058 80608065 8070 ꞏ300ꞏ

The same code on other products

·