Error 2415 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: PWCTRL OUT not allowed without master spindle in the channel.

Detection

During execution.

Cause

The power control is applied to the master spindle. An attempt was made to activate the power control and there is no master spindle active.

Solution

Select a master spindle (# MASTER) before activating the power control.

·