Error 2387 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Tool monitoring not valid in work zone.

Detection

During block preparation.

Cause

Tool monitoring in the work zone does not have the right value. There are 2 possibilities.

  • The value programmed in G122 is wrong.
  • The value restored after some data restoring process (startup, reset, tool inspection) is wrong.

Solution

Program the right value for tool monitoring; from 0 to 2.

  • In the first case, program a correct value in parameter "I"of function G122.
  • In the second case, write from the PLC the right value in the variable "G.ZONETOOLWATCH[zone]".

·