Error 2387 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Tool monitoring not valid in work zone.
Detection
During block preparation.
Cause
Tool monitoring in the work zone does not have the right value. There are 2 possibilities.
- The value programmed in G122 is wrong.
- The value restored after some data restoring process (startup, reset, tool inspection) is wrong.
Solution
Program the right value for tool monitoring; from 0 to 2.
- In the first case, program a correct value in parameter "I"of function G122.
- In the second case, write from the PLC the right value in the variable "G.ZONETOOLWATCH[zone]".