Error 2376 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: #LSFIT, calculation error (SVBK), check input data.
Detection
During execution.
Cause
Kinematics calibration. The cycle cannot finish the adjustment with the palpation or input data.
Solution
Correct input data or number and/or positions of palpations.