Error 1650 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: User direct transformation function not found

Detection

During execution.

Cause

The McsToPcs coordinates function is missing when trying to do a transformation from machine coordinates to part coordinates in a user kinematics.

Solution

Check the user kinematics integration process.

·