Error 1485 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: #WAIT/#MEET not effective

Detection

During execution.

Cause

The #WAIT or #MEET instruction is not going to generate any wait because the synchronization mark is programmed for the same channel as the instructions.

Solution

Check the program.

·