Error 1318 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: #CS ON/#ACS ON: No changes allowed with the active coordinate system
Detection
During execution.
Cause
The CNC has tried to change the parameters of an active coordinate system.
Solution
Check the program. The CNC does not allow to change the parameters of an active coordinate system; it does allow changing the parameters of a coordinate system that has been already defined, but it is not active.