Error 1247 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Threading is not possible while G96 is active

Detection

During execution.

Cause

The CNC has tried to execute a rigid tapping (G63) while function G96 is active (constant surface speed).

Solution

Activate the constant turning speed mode (G97).