Error 1082 · CNC 8055 T

Message: The probe signal has not been received.

Detection

During execution.

Cause

The possible causes are:

  1. When programming a "PROBE" canned cycle, the probe has moved the maximum safety distance of the cycle without the CNC receiving the probe signal.
  2. When programming the "G75" function, it has reached the end point and the CNC has not received the signal from the probe. (Only when general machineparameter PROBERR(P119)=YES).

Solution

The solution for each cause is:

  1. Check that the probe is connected properly.

The maximum probing distance (in PROBE cycles) depends on the safety distance "B". To increase this distance, increase the safety distance.

  1. If PROBERR(P119)=NO, this error will not be issued when the end point is reached without having received the probe signal (only with "G75").

The same code on other products

·