Error 1082 · CNC 8055 M
Message: The probe signal has not been received.
Detection
During execution.
Cause
The possible causes are:
- When programming a "PROBE" canned cycle, the probe has moved the maximum safety distance of the cycle without the CNC receiving the probe signal.
- When programming the "G75" function, it has reached the end point and the CNC has not received the signal from the probe. (Only when general machine parameter PROBERR(P119)=YES).
Solution
The solution for each cause is:
- Check that the probe is connected properly.
The maximum probing distance (in PROBE cycles) depends on the safety distance "B". To increase this distance, increase the safety distance.
- If PROBERR(P119)=NO, this error will not be issued when the end point is reached without having received the probe signal (only with "G75").