Error 9525 · CNC 8058 / 8060 / 8065 · CNC 8070

Message: INDUCTOSYN: INC signal too short.

Detection

On startup or normal operation of the system.

Cause

Incremental signal level of the inductosyn/resolver feedba ck device too low.

Solution

The possible solutions are:

  • Check the gain and phase values of the ABSIND module with the adjustment software.
  • Check the cable and the connection between the ABSIND module and the inductosyn/resolver feedback device.
  • If the error persists and cannot be changed with the previous actions, try replacing the ABSIND module and/or the cable associated with that feedback. If the error persists, contact Fagor Automation.