Error 9332 · CNC 8058 / 8060 / 8065 · CNC 8070
Message: Remote COUNTERTYPE and COUNTERID 0 are incompatible with each other
Detection
On CNC power-up or when validating the machine parameters.
Cause
On analog axes with remote feedback input (parameter COUNTERTYPE), parameter COUNTERID cannot be zero.
Solution
Check the machine parameters. Check the type of feedback assigned to the axis (parameter COUNTERTYPE). On analog axes with remote feedback input, p a r a m e t e r C O U N T E R I D i n d i c a t e s t h e l o g i c a d d r e s s o f t h e d r i v e a nd it cannot be zero.