Error 0106 · CNC 8058 / 8060 / 8065 · CNC 8070

Message: Parameters cannot be validated: Spindle or axis in motion or in synchronization

Detection

During the validation of the machine parameters.

Cause

The user has tried to validate a machine parameter table while a spindle or an axis is moving. An axis may be moving as a result of a command of independent axis.

Solution

Stop the axis or spindle movement.