Error 0083 · CNC 8058 / 8060 / 8065 · CNC 8070

Message: The master and slave axes must be of the same type (DRIVETYPE)

Detection

During the validation of the machine parameters.

Cause

The two axes of a gantry axis have different types of drives; analog or Sercos or Mechatrolink.

Solution

The axes of a gantry pair must have the same type of drive (parameter DRIVETYPE).