Error 0051 · CNC 8058 / 8060 / 8065 · CNC 8070
Message: The master and slave axes must have certain parameters with the same value
Detection
During the validation of the machine parameters.
Cause
The two axes of a gantry axis do not have the same properties.
Solution
Check the gantry axes table and/or the following machine parameters of the axes.
- The linear axes must have parameters AXISMODE, FACEAXIS and LONGAXIS set the same way.
- The rotary axes must have parameters AXISMODE, SHORTESTWAY and CAXIS set the same way.