Error 0050 · CNC 8058 / 8060 / 8065 · CNC 8070
Message: The master and slave axes must be of the same type (AXISTYPE)
Detection
During the validation of the machine parameters.
Cause
Both axes of a gantry pair are not of the same type; linear or rotary.
Solution
The axes of a gantry pair must be of the same type, linear or rotary (parameter AXISTYPE). Check the gantry axes table and/or the AXISTYPE parameter of both axes.