Error 5005 · CNC 8055 T
Message: Presence control error detected by the CNC
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of all channels.
Besides this, it activates the external emergency output.
Cause
The CNC detects that the node has reset itself or is connected wrong.
Solution
Check cables and connections.
2 Transmission queue full, the message cannot be sent.
128 Bus Off, the bus has been deactivated due to too many errors.
129 CAN warning, there are more than 96 errors at the bus, step prior to the buss off error.
130 Loss of message received or too many messages received. Usually due to wrong speed for the cable length.
131 The CNC has switched to an inoperative state in the bus (internal).
2 Check the connection between the CNC and first node.
128 Check cables and connections.
129 Check cables and connections.
130 Check machine parameter IOCANSPE (P88).
131 Check cables and connections.