Error 2045 · CNC 8055 M · CNC 8055 T
Message: G51 with FAGOR filters is incompatible with general parameter IPOTIME.
Detection
During execution.
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of its channel.
Besides this, it activates the external emergency output.
Cause
If g.m.p. IPOTIME (P73) is other than ·0·, even if FAGOR filters are active (bit 15 of g.m.p. LOOKATYP=1), when programming G51, the FAGOR filters do not start working.