Error 2019 · CNC 8055 M · CNC 8055 T

Message: PLC’s RAM memory error.

Detection

While starting the CNC or during diagnoses.

Effect

It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.

If it is in execution, it interrupts the execution of the part program of the CNC of its channel.

Besides this, it activates the external emergency output.

Cause

A defect has been found in the PLC’s RAM memory.

Solution

Replace the PLC board. Contact the Service Department.

·