Error 2011 · CNC 8055 M · CNC 8055 T
Message: Maximum temperature exceeded
Detection
Any time.
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of its channel.
Besides this, it activates the external emergency output.
Cause
The CNC’s internal temperature has been exceeded. The causes may be:
Electrical cabinet poorly ventilated. Axis board with some defective component.
Solution
Turn the CNC and wait until it cools off. If the error persists, a component of the board may be defective. In that case, replace the board. Contact the Service Department.