Error 1105 · CNC 8055 M · CNC 8055 T
Message: Do not change gears while the spindles are synchronized
Detection
During execution.
Cause
While the spindles are synchronized, a gear changing "M" function (M41 to M44) has been executed or the programmed "S" involves a gear change (with automatic gearchanger).
Solution
First, cancel spindle synchronization (G78S).