Error 1103 · CNC 8055 M · CNC 8055 T
Message: Do not synchronize spindles without homing them first
Detection
During execution.
Cause
An attempt has been made to synchronize the spindle without homing them first.
Solution
Before activating the synchronization, both spindles must be homed using the "M19" function.