Error 1042 · CNC 8055 T
Message: Wrong parameter value in canned cycle
Detection
During execution.
Cause
When defining a canned cycle, a parameter has been defined with the wrong value.
Perhaps, a parameter that only takes positive values has been assigned a negative value (or zero).
Solution
Correct the definition of parameters:
In the "Pattern repeat cycle":
Parameter "C" only takes positive values greater than zero. Parameter "A" only admits values of 0 or 1. Parameter "J" only takes positive values greater than zero.
In the canned cycle for "roughing along the Z axis" or "roughing along the X axis", parameter "C" only takes positive values greater than zero.
In the " Axial drilling/tapping canned cycle":
Parameter "I" only admits values other than zero. Parameter "B" only takes positive values or zero.
In the canned cycle for "facing curved sections" or "turning curved sections", parameter "C" only takes positive values greater than zero.
In the "Face threading canned cycle" or "Longitudinal threading canned cycle", parameter "I", "B", "E" or "C" has been defined with a zero value.
In the canned cycle for "grooving along the Z axis" or "grooving along the X axis", parameter "C" only takes positive values greater than zero.
In the canned cycle for "Face drilling/tapping" or "Longitudinal drilling/tapping":
Parameter "I" only admits values other than zero. Parameter "B" only takes positive values or zero. Parameter "J" only takes positive values greater than zero.
In the canned cycle for "slot milling on the face" or "slot milling on the side", the slot dimension cannot be zero and parameters "I" and "J" only take positive values greater than zero.