Error 1000 · CNC 8055 M · CNC 8055 T

Message: There is no enough path information.

Detection

During execution.

Cause

The program contains too many blocks without information about the path to apply tool radius compensation, rounding, chamfer or tangential entry or exit.

Solution

In order to carry out these operations, the CNC needs to know in advance the path to follow; therefore, there cannot be more than 48 blocks in a row without information about the path to follow.