Error 0113 · CNC 8055 M · CNC 8055 T

Message: Table limits exceeded.

Detection

While editing tables.

Cause

The possible causes are:

  1. In the tool offset table, an attempt has been made to define a tool offset with a greater number than allowed by the manufacturer.
  2. In the parameter tables, an attempt has been made to define a nonexistent parameter.

Solution

The tool offset number must be smaller than the one allowed by the manufacturer.

The same code on other products

·