Error 0061 · CNC 8055 M · CNC 8055 T
Message: ELSE not associated with IF.
Detection
While editing at the CNC or while executing a program transmitted via DNC.
Cause
The possible causes are:
- While editing in High level language, when editing the "ELSE" instruction without having previously programmed an "IF".
- When programming in high level language, an "IF" is programmed without associating it with any action after the condition.
Solution
Remember that the programming formats for this instruction are:
(IF (condition) )(IF (condition ELSE )
If the condition is true, it executes the , otherwise, it executes .