Error 0049 · CNC 8055 M · CNC 8055 T
Message: Point incompatible with active plane.
Detection
While editing at the CNC or while executing a program transmitted via DNC.
Cause
The possible causes are:
- When trying to do a circular interpolation, the end point is not in the active plane.2. When trying to do a tangential exit in a path that is not in the active plane.
Solution
The solution for each cause is:
- Maybe a plane has been defined with "G16", "G17", "G18" or "G19". In this case, circular interpolations can only be carried out on the main axes defining that plane.
To define a circular interpolation in another plane, it must be defined beforehand.
- Maybe a plane has been defined with "G16", "G17", "G18" or "G19". In this case, corner rounding, chamfers and tangential entries/exits can only be carried out on the main axes defining that plane. To do it in another plane, it must be defined beforehand.