Error 2049 · CNC 8055 M
Message: Parameter TYPE=2 is incompatible with general parameter SMOTIME.
Detection
During execution.
Effect
It stops the movement of the axes and the spindle, eliminating all the enable signals and canceling all the analog outputs of the CNC. When detected from the position loop, it opens the position loop and sets the LOPEN mark to ·1·.
If it is in execution, it interrupts the execution of the part program of the CNC of its Besides this, it activates the external emergency output.
Cause
If FAGOR filters are active (a.m.p. TYPE=2) and g.m.p. SMOTIME (P58) is other than , the FAGOR filters do not kick in (don't start working).