Error 0205 · CNC 8055 M

Message: Incorrect digitizing method.

Detection

During execution.

Cause

Point-to-point digitizing has been defined, but the CNC is not in jog mode (it is in either in simulation or execution mode, instead).

Solution

To execute point-to-point digitizing, the CNC must be in jog mode.

·