Error 0198 · CNC 8055 M

Message: Deflection out of range.

Detection

During execution.

Cause

In the tracing cycle "G23", a nominal probe deflection has been defined which is greater than the value set by machine parameter.

Solution

Program a smaller nominal probe deflection.

·