Error codes
Look up an error or alarm code from your Fagor CNC, drive or digital readout and see its cause and solution, with a link to the page in the manual.
All codes (4.799)
- 3812 Handwheel refresh error CNCelite 8058 / 8060 / 8065 / 8070
- 3812 Handwheel refresh error CNC 8070
- 4000 Sercos ring error CNC 8055 M · CNC 8055 T
- 4001 Parameter LOOPTIME different at the CNC and at the drive CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4001 Undefined class 1 error CNC 8055 M · CNC 8055 T
- 4002 Overload ( 201...203 ) CNC 8055 M
- 4002 Overload (201...203) CNC 8055 T
- 4002 Parameter OPMODE different at the CNC and at the drive CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4003 Overtemperature at the drive ( 107 ) CNC 8055 M
- 4003 Overtemperature at the drive (107) CNC 8055 T
- 4003 Parameter AXISMODE different at the CNC and at the drive CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4004 Overtemperature at the motor ( 108 ) CNC 8055 M
- 4004 Overtemperature at the motor (108) CNC 8055 T
- 4004 Parameter G00FEED higher at the CNC than at the drive CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4005 Following error monitoring not active at the drive CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4005 Overtemperature at the heatsink ( 106 ) CNC 8055 M
- 4005 Overtemperature at the heatsink (106) CNC 8055 T
- 4006 Drive parameter SP100 must be 0 CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4006 Voltage control error (100...105) CNC 8055 M · CNC 8055 T
- 4007 Feedback error ( 600...606 ) CNC 8055 M
- 4007 Feedback error (600...606) CNC 8055 T
- 4007 The Sercos spindle needs a gain other than 0 CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4008 Error at the power bus ( 213...215 ) CNC 8055 M
- 4008 Error at the power bus (213...215) CNC 8055 T
- 4008 Sercos ring Error+ because the drive has been reset CNC 8058 / 8060 / 8065 · CNC 8070
- 4008 Sercos ring Error+ because the drive has been reset CNCelite 8058 / 8060 / 8065 / 8070
- 4009 Overcurrent ( 212 ) CNC 8055 M
- 4009 Overcurrent (212) CNC 8055 T
- 4009 Too many variables in a Sercos telegram CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
- 4010 Overvoltage at the power bus ( 304/306 ) CNC 8055 M
last + 4 && y > 160 ? true : (y < last - 4 ? false : hide); last = y"