Error 0205 · CNC 8055 M
Message: Incorrect digitizing method.
Detection
During execution.
Cause
Point-to-point digitizing has been defined, but the CNC is not in jog mode (it is in either in simulation or execution mode, instead).
Solution
To execute point-to-point digitizing, the CNC must be in jog mode.