Error 0106 · CNC 8055 M · CNC 8055 T

Message: Program numerical format.

Detection

While editing at the CNC or while executing a program transmitted via DNC.

Cause

While programming in high level language, an "IB" instruction has been edited with non-numeric format.

Solution

Remember that the programming format for this instruction is:

(IB (expression) = INPUT "text", format)

Where "format" must be a signed number with 6 entire digits and 5 decimals at the most.

If the "," character is entered after the text, the CNC expects the format.

The same code on other products

·