Error 0083 · CNC 8055 T

Message: Incomplete operation.

Detection

While editing at the CNC or while executing a program transmitted via DNC.

Cause

While programming in high level language, the "IF" instruction has been edited without the condition between brackets.

Solution

Remember that the programming formats for this instruction are:

(IF (condition) )

(IF (condition ELSE )

If the condition is true, it executes the , otherwise, it executes .

The same code on other products

·