Error 0061 · CNC 8055 M · CNC 8055 T

Message: ELSE not associated with IF.

Detection

While editing at the CNC or while executing a program transmitted via DNC.

Cause

The possible causes are:

  1. While editing in High level language, when editing the "ELSE" instruction without having previously programmed an "IF".
  2. When programming in high level language, an "IF" is programmed without associating it with any action after the condition.

Solution

Remember that the programming formats for this instruction are:

(IF (condition) )(IF (condition ELSE )

If the condition is true, it executes the , otherwise, it executes .

The same code on other products

·