Error 9646 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Fagor digital feedback. Supply voltage out of range.
Detection
On startup or normal operation of the system.
Cause
The supply voltage must be between 5.3 V and 4.1 V.
Solution
The possible solutions are:
- Check that the power cable of the rotary or linear encoder is not damaged.
- Check that the length of the cable is the right one and that the wire connection is OK.