Error 9636 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: INDUCTOSYN: Linear encoder unstable on Power-ON.

Detection

During system startup.

Cause

The position read when initializing the ABSIND module is unstable.

Solution

The possible solutions are:

  • Check that the axis is not moving while starting up or initializing the ABSIND module.
  • Check the cable and the connection between the ABSIND module and the inductosyn/resolver feedback device.
  • Check the ground connections in the electrical cabinet (electrical noise on the signals).
  • If the error persists and cannot be changed with the previous a c t i o n s , t r y r e p l a c i n g the ABSIND module and/or the cable associated with that feedback. If the error persists, contact Fagor Automation.

·