Error 6005 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070

Message: Error when selecting the work frequency of the BUS CAN

Detection

During system startup.

  • 4 / -5 Different memory structure for the PC and for the COMPCI (possibly different

Cause

One or several nodes are not tuned in to the frequency set by parameter.

versions).

Solution

Check the following. If the error persists, contact the Service Department.

  • 6 Error in EnableCyclicRead(MD_JOG).-7 Problems when identifying nodes (same node group and number).
  • Check that the length of the CAN cable is the right one for the frequency.
  • 8 Problems when identifying nodes (an extra node has been found).
  • Check in diagnosis mode that the CNC recognizes all the modules.
  • Use the itfcCAN.exe tool to check the CAN bus (only service technicians).
  • 9 Wrong IniCan accessing password.-10 Failure during the hardware test of the COMPCI.

·