Error 4633 · CNC 8058 / 8060 / 8065 · CNC 8070 · CNCelite 8058 / 8060 / 8065 / 8070
Message: Node communication error.
Detection
During CNC power-up or after a reset.
Cause
A communication error occurred with a Sercos III slave after a reset, reading of the version or reading of the Hardware ID.
Solution
Check the wiring, connections and power supply of the slaves. If the error persists, contact Fagor Automation.